EasyManua.ls Logo

Siemens G130 - Fig. 3-207 9549 - Overview

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1333
3 Function diagrams
3.25 Terminal Module 31 (TM31)
Fig. 3-207 9549 – Overview
Function diagram
- 9549 -
87654321
DO: TM31
SINAMICS
12.03.13 V04.08.00
Terminal Module 31 (TM31) - Overview
X520
1
2
3
4
5
6
DI 0
DI 1
DI 2
DI 3
M
M1
X530
1
2
3
4
5
6
DI 4
DI 5
DI 6
DI 7
M
M2
M
M
+24 V DC
to the next
device
M
+
M
+
Simulation for DI 0...DI 11
1
0
1 = Simulation on
p4095.0...11
Simulation signals
p4096.0...11
r4022.0
1
r4023.0
r4022.3
1
r4023.3
... ...
r4022.4
1
r4023.4
r4022.7
1
r4023.7
... ...
1
0
1
0
p4038
1
r4022.8 r4023.8
p4028.8
p4028.11
p4041
1
r4022.11 r4023.11
...
...
...
...
...
A
D
r4055[0] [%]
A
D
r4055[1] [%]
X521
1
2
3
4
5
6
7
8
AI 0+
AI 0-
AI 1+
AI 1-
P10
M
N10
M
X522
1
AO 0V+
2
3
4
5
6
7
8
AO 0-
AO 0A+
AO 1V+
AO 1-
AO 1A+
+Temp
-Temp
A
D
p4071[1]
A
D
p4071[0]
DO 0
DO 1
X542
1
2
3
4
5
6
X541
1
2
3
4
5
6
DI/D0 8
DI/D0 9
DI/D0 10
DI/D0 11
M
+
NC 0
COM
NO 0
NC 1
COM
NO 1
p4030
p4031
[9566], [9568] 2 analog inputs
[9572] 2 analog outputs
[9556] 2 digital outputs (relay)
[9560], [9562] 4 digital inputs/outputs
[9552] 4 digital inputs, electrically isolated
[9550] 4 digital inputs, electrically isolated
r4021.0...11
r4104.1
r4104.0
Alarm:
Overtemperature
sensor TM31
Fault:
Overtemperature
sensor TM31
A
D
[9576] Input for temperature sensor
A35211
F35207
r4105
Temp KTY/PTC
p4048.0
1
0
1
1
0
1
p4048.1
X540
1
+24 V
2
3
4
5
6
7
8
+24 V
+24 V
+24 V
+24 V
+24 V
+24 V
+24 V
Auxiliary voltage for
the digital inputs
fp_9549_51_eng.vsd
X500
X501
DRIVE-CLiQ socket 0
DRIVE-CLiQ socket 1
=
~
+M
p4099 (4000.00 μs)
r4022.0...11
1
r4023.0...11
X524
+24 V

Table of Contents