SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1103
3 Function diagrams
3.2 Explanation of the function diagrams
Fig. 3-2 1021 – Explanation of the symbols (part 2)
- 1021 -
Function diagram
87654321
fp_1021_51_eng.vsd
DO: All objects
SINAMICS
26.11.15 V04.08.00
Explanations on the function diagrams - Explanation of the symbols (part 2)
Pre-assigned binectors and connectors
Symbols for computational and closed-loop
control functions
Threshold value switch 1/0
Outputs at y a logical "1" if x < S.
Simple changeover switch
The switch position is shown according to
the factory setting of pxxxx (in this case
switch position 1).
Limiter
x is limited to the upper limit LU and the lower limit
LL and output at y.
The digital signals MLU and MLL have the value
"1", if the upper or lower limit is active.
p2900[D]
Fixed value 1 [%]
p2901[D]
Fixed value 2 [%]
-10 000.00...10 000.00 [%]
p2900[D] (0.00)
-10 000.00...10 000.00 [%]
p2901[D] (0.00)
Fixed percentage values
S
y
x
1
0
Threshold value switch 0/1
Outputs at y a logical "1" if x > S.
0
1
y
x
S
Sample & Hold element
Sample and hold element.
y = x if SET = 1
(not saved retentively at POWER OFF)
1
0
pxxxx
Fixed speed values
-210 000.000...210 000.000 [rpm]
p1001[D] (0.000)
p1001[D]
n_set_fixed 1
-210 000.000...210 000.000 [rpm]
p1015[D] (0.000)
p1015[D]
n_set_fixed 15
Fixed torque value
-100 000.00...100 000.00 [Nm]
p2930[D] (0.00)
p2930[D]
Fixed value M [Nm]
Switch symbol
Threshold value switch 1/0 with
hysteresis
Outputs at y a logical "1" if x < S.
If x >= S + H, then y returns to 0.
0
1
S
H
y
x
Threshold value switch 0/1 with
hysteresis
Outputs at y a logical "1" if x > S.
If x <= S  H, then y returns to 0.
0
1
H
S
y
x
r2902[0...14]
Fixed values [%]
p2902[0...14] (0.00)
SET
S & H
xy
Sign reversal
y = -x
Absolute value generator
y = |x|
Divider
y =
Comparator
y = 1 if the analog signal x > 0, i.e. is
positive.
Monitoring
Axxxxx
or
Fxxxxx
Symbol for monitoring
Monitoring
In the bottom right-hand corner of
the diagram.
x
1
x
2
Multiplier
y = x
1
* x
2
Symbols for logic functions
Symbols for computational and
closed-loop control functions
p2902[0] = +0 %
p2902[1] = +5 %
p2902[2] = +10 %
p2902[3] = +20 %
p2902[4] = +50 %
p2902[5] = +100 %
p2902[6] = +150 %
p2902[7] = +200 %
p2902[8] = -5 %
p2902[9] = -10 %
p2902[10] = -20 %
p2902[11] = -50 %
p2902[12] = -100 %
p2902[13] = -150 %
p2902[14] = -200 %
MLL
MLU
x
y
LU
LL
dx
dt
xy
Y =
dt
dx
Differentiator
xy
>0
x
2
x
1
y
y
x
2
x
1
xy
-1
xy
Exclusiv-OR/XOR
y = 1 when x
1
x
2
is.
Comparator
y = 1 when x
1
= x
2
is.
NOT element
R/S flip-flop
S/R = setting input/reset input
Q = non-inverted output
= inverted output
Q
With a simultaneous 1-signal at the R and
S inputs, the S input dominates.
AND element
=1
x
1
y
x
2
y
=
x
2
x
1
R Q
S Q
1
OR element
With logical inversion of an input.
1
&
Logical inversion (negation).