EasyManua.ls Logo

Siemens G130 - Fig. 3-101 2892 - Configuration, F-DI;F-DO test

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1213
3 Function diagrams
3.12 Safety Integrated TM54F
Fig. 3-101 2892 – Configuration, F-DI/F-DO test
- 2892 -
Function diagram
87654321
fp_2892_51_eng.vsd
DO: TM54F_MA, TM54F_SL
SINAMICS
06.07.15 V04.08.00
SI Extended Functions - TM54F configuration, F-DI/F-DO test
p10000 (12.00 ms)
Drive 1
p10011[0] (1)
Drive 2
p10011[1] (1)
Drive 3
p10011[2] (1)
Drive 4
p10011[3] (1)
Drive 5
p10011[4] (1)
Drive group assignment
SI FCP Timer
0.00...8760.00 [h]
p10003 (8.00)
(0)
SI FCP F-DI/DO s_src
p10007
T0
Drive group 1
Drive group 2
Drive group 3
Drive group 4
Drive 6
p10011[5] (1)
A35012
"Test stop active"
F35013
"Test stop error"
A35014
"Test stop required"
Test F-DI
Test F-DO
SI F-DI enab test
p10041
SI F-DO FS act
p10046
Test stop
Restart timer (on successful test stop)
r10053.3 DI 23
r10053.0 DI 20
r10053.1 DI 21
r10053.2 DI 22
p10010[0]
Drive 1
p10010[1]
Drive 2
p10010[2]
Drive 3
p10010[3]
Drive 4
p10010[4]
Drive 5
p10010[5]
Drive 6
[2895.8]
[2895.8]
[2895.8]
[2895.8]
Drive object
Drive group
Drive object assignment

Table of Contents