2 Parameters
2.2 List of parameters
Note: TEC: Technology Extension
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays the interface version of all the Technology Extensions installed on the memory card/device memory.
r4990[0]: Interface version of Technology Extension 1
r4990[1]: Interface version of Technology Extension 2, ...
Dependency: Refer to: r4985, r4986, r4987, r4988, r4989, r4991, r4992, r4993, r4994
Notice: If there is no Technology Extension, then it is not possible to access an index.
Note: TEC: Technology Extension
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays the GUIDs of all the Technology Extensions installed on the memory card/device memory.
r4991[0...15]: GUID of Technology Extension 1
r4991[16]: Major information of Technology Extension 1
r4991[17]: Minor information of Technology Extension 1
r4991[18...33]: GUID of Technology Extension 2
r4991[34]: Major information of Technology Extension 2
r4991[35]: Minor information of Technology Extension 2, ...
Dependency: Refer to: r4985, r4986, r4987, r4988, r4989, r4990, r4992, r4993, r4994
Notice: If there is no Technology Extension, then it is not possible to access an index.
Note: TEC: Technology Extension
Description: Displays the GUIDs of all the Technology Extensions installed on the memory card/device memory.
r4992[0...15]: GUID of Technology Extension 1
r4992[16]: Major information of Technology Extension 1
r4992[17]: Minor information of Technology Extension 1
r4992[18...33]: GUID of Technology Extension 2
r4992[34]: Major information of Technology Extension 2
r4992[35]: Minor information of Technology Extension 2, ...
Dependency: Refer to: r4985, r4986, r4987, r4988, r4989, r4990, r4991, r4993, r4994
r4990[0...n] TEC interface version / TEC interf_vers
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: r4985 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r4991[0...n] TEC GUID / TEC GUID
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned8 Dyn. index: r4987 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r4992[0...n] TEC GUID ES / TEC GUID ES
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned8 Dyn. index: r4987 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -