EasyManua.ls Logo

Siemens G130 - p4641[0...2] OEM encoder diagnostic signal selection; OEM enc diag sel; p4642 Test function encoder fault; Test encoder fault; p4650 Encoder functional reserve component number; Enc fct_res num; r4651[0...3] Encoder functional reserve; Enc fct_reserve

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
686 List Manual (LH2), 07/2016, A5E03263479A
Description: Sets the trace functionality for OEM encoder manufacturers.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Description: Test function to initiate an encoder fault
For a 0/1 transition, an encoder fault is output at the currently used motor encoder.
For a 1/0 transition and an alarm acknowledgment, the encoder fault that was issued is cleared.
Notice: It is not permissible that a data set is switched over between issuing and deleting an encoder fault.
Description: Sets the component number (p0141) of the encoder whose functional reserve is to be displayed (r4651).
Dependency: Refer to: r4651
Description: Displays the functional reserve of the encoder selected via p4650.
0 ... 25 %:
The function limit has been reached. A service is recommended.
26 ... 100 %:
The encoder is working in the specified range.
Index: [0] = Function reserve 1
[1] = Function reserve 2
[2] = Function reserve 3
[3] = Function reserve 4
Dependency: Refer to: p4650
p4641[0...2] OEM encoder diagnostic signal selection / OEM enc diag sel
VECTOR_G Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 65535 0
p4642 Test function encoder fault / Test encoder fault
VECTOR_G Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 0
p4650 Encoder functional reserve component number / Enc fct_res num
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 399 0
r4651[0...3] Encoder functional reserve / Enc fct_reserve
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]

Table of Contents