Siemens G130 - r7224[0...n] CO: Par_circuit phase current actual value phase V; I_phase V act val; r7225[0...n] CO: Par_circuit phase current actual value phase W; I_phase W act val; r7226[0...n] CO: Par_circuit phase current actual value phase U offset; I_phase U offset; r7227[0...n] CO: Par_circuit phase current actual value phase V offset; I_phase V offset

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
764 List Manual (LH2), 07/2016, A5E03263479A
Description: Displays the measured actual value of phase V as peak value.
The summed value of all power units is displayed in r0069[1].
Description: Displays the measured actual value of phase W as peak value.
The summed value of all power units is displayed in r0069[2].
Description: Displays the measured offset of phase U as peak value.
The summed value of all power units is displayed in r0069[3].
Description: Displays the measured offset of phase V as peak value.
The summed value of all power units is displayed in r0069[4].
Description: Displays the measured offset of phase W as peak value.
The summed value of all power units is displayed in r0069[5].
r7224[0...n] CO: Par_circuit phase current actual value phase V / I_phase V act val
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7225[0...n] CO: Par_circuit phase current actual value phase W / I_phase W act val
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7226[0...n] CO: Par_circuit phase current actual value phase U offset / I_phase U offset
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7227[0...n] CO: Par_circuit phase current actual value phase V offset / I_phase V offset
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7228[0...n] CO: Par_circuit phase current actual value phase W offset / I_phase W offset
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]