List Manual (LH2), 07/2016, A5E03263479A
365
2 Parameters
2.2 List of parameters
Description: Sets the delay time for closing the brake at standstill.
After this time has expired, if the "close brake at standstill" or OFF1/OFF3 is present, the brake is closed and the
pulses are suppressed.
For p1276 = 300.000 s, the timer is deactivated - this means that the timer output is always zero.
Description: Sets the delay time for the signal "braking threshold exceeded" (BO: r1229.6).
Dependency: Refer to: p1220, p1221, r1229
Description: Sets the brake control type (with or without diagnostics evaluation).
Example for brake control with diagnostics evaluation.
- brake control in the Motor Modules in booksize format
- Safe Brake Relay for AC Drive
Example for brake control without diagnostics evaluation.
- Brake Relay for AC Drive
Value: 0: Brake control with diagnostics evaluation
1: Brake control without diagnostics evaluation
Note: If the configuration of the motor holding brake (p1215) is set to "no holding brake present" when booting, then an
automatic identification of the motor holding brake will be carried out. If a brake control is detected without
diagnostics evaluation (e.g. Brake Relay for AC Drive), then the parameter is set to "brake control without diagnostics
evaluation".
It is not permissible to parameterize "brake control without diagnostics evaluation" and also enable "safe brake
control" (p1278 = 1, p9602 = 1, p9802 = 1).
Description: Sets the signal source for the OR/AND logic operation.
Dependency: Refer to: r1229
p1276 Motor holding brake standstill detection bypass / Brk standst bypass
VECTOR_G (Ext
brake)
Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2704
P-Group: Functions Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.000 [s] 300.000 [s] 300.000 [s]
p1277 Motor holding brake braking threshold delay exceeded / Del thresh exceed
VECTOR_G (Ext
brake)
Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2707
P-Group: Functions Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.000 [s] 300.000 [s] 0.000 [s]
p1278 Brake control diagnostics evaluation / Brake diagnostics
VECTOR_G Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Functions Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p1279[0...3] BI: Motor holding brake OR/AND logic operation / Brake OR AND
VECTOR_G (Ext
brake)
Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2707
P-Group: Functions Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0