2 Parameters
2.2 List of parameters
SINAMICS G130/G150
736 List Manual (LH2), 07/2016, A5E03263479A
Notice: If there is no Technology Extension, then it is not possible to access an index.
Note: TEC: Technology Extension
Description: Displays the activation status of the Technology Extensions installed on the memory card/device memory.
r4993[0]: Activation of Technology Extension 1
r4993[1]: Activation of Technology Extension 2, ...
Value: 0: Technology Extension inactive
1: Technology Extension active
Dependency: Refer to: r4985, r4986, r4987, r4988, r4989, r4990, r4991, r4992, r4994
Notice: If there is no Technology Extension, then it is not possible to access an index.
Note: TEC: Technology Extension
Description: Displays the properties of all the Technology Extensions installed on the memory card/device memory.
r4994[0]: Property of Technology Extension 1
r4994[1]: Property of Technology Extension 2, ...
Dependency: Refer to: r4985, r4986, r4987, r4988, r4989, r4990, r4991, r4992, r4993
Notice: If there is no Technology Extension, then it is not possible to access an index.
Note: TEC: Technology Extension
The parameter is only for internal Siemens diagnostics.
Description: Displays the external version of all the Technology Extensions installed on the memory card/device memory.
r4995[0]: External version of Technology Extension 1
r4995[1]: External version of Technology Extension 2, ...
Dependency: Refer to: r4985, r4986, r4987, r4988, r4990, r4991, r4992, r4993, r4994
Notice: If there is no Technology Extension, then it is not possible to access an index.
r4993[0...n] TEC activation status / TEC act stat
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Integer16 Dyn. index: r4985 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 -
r4994[0...n] TEC properties / TEC property
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: r4985 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Properties diagnostics bit 0 Yes No -
01 Properties diagnostics bit 1 Yes No -
02 Properties diagnostics bit 2 Yes No -
03 OEM No Yes -
04 Properties diagnostics bit 4 Yes No -
05 Properties diagnostics bit 5 Yes No -
06 Properties diagnostics bit 6 Yes No -
r4995[0...n] TEC external version / TEC ext version
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: r4985 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -