2 Parameters
2.2 List of parameters
Description: Sets the parameters with reference value in p0514[9] for the specific scaling.
p0524[0]: parameter number
p0524[1]: parameter number
p0524[2]: parameter number
...
p0524[19]: parameter number
Dependency: Refer to: p0514
Description: Sets the system of units for the controller gains.
Value: 0: Representation physical/% (p0505)
1: Representation no dimensions (referred)
Note: For VECTOR (r0107) the following applies:
The parameter is pre-assigned a value of 1 and cannot be changed.
Description: Sets the system of units for the controller gains.
Value: 0: Representation physical/% (p0505)
1: Representation no dimensions (referred)
Note: The parameter is pre-assigned a value of 0 and cannot be changed.
Description: Sets the bearing version.
Corresponding to the bearing version entered, its code number (p0531) is automatically set.
0 = No data
1 = Manual entry
101 = STANDARD
p0524[0...19] Scaling specific parameters referred to p0514[9] / Scal spec p514[9]
VECTOR_G, B_INF Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0
p0528 Controller gain system of units / Ctrl_gain unit_sys
VECTOR_G Can be changed: C2(5) Calculated: - Access level: 4
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Applications Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 1
p0528 Controller gain system of units / Ctrl_gain unit_sys
ENC Can be changed: C2(5) Calculated: - Access level: 4
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Applications Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p0530[0...n] Bearing version selection / Bearing vers sel
VECTOR_G Can be changed: C2(1, 3) Calculated: - Access level: 1
Data type: Unsigned16 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Unit group: - Unit selection: -
Not for motor type: SESM Scaling: - Expert list: 1
Min Max Factory setting
0 104 0