EasyManua.ls Logo

Siemens G130 - Fig. 3-205 9220 - Control word, CANopen

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Function diagrams
3.24 Communication Board CAN10 (CBC10)
SINAMICS G130/G150
1330 List Manual (LH2), 07/2016, A5E03263479A
Fig. 3-205 9220 – Control word, CANopen
- 9220 -
Function diagram
87654321
fp_9220_51_eng.vsd
DO: A_INFM2C, SERVO, VECTOR, VECTOR3P, VECTORGL, VECTORMV, VECTORSL
SINAMICS
04.07.13 V04.08.00
Communication Board CAN10 (CBC10) - Control word, CANopen
STW1.0
STW1.1
STW1.2
STW1.3
STW1.8
STW1.9
STW1.11
STW1.12
STW1.13
STW1.14
STW1.15
STW1.7
STW1.10
p0848[0] = r8890.2
p0852[0] = r8890.3
p2103[0] = r8890.7
-
-
-
pxxxx[y] = r8890.11
pxxxx[y] = r8890.12
pxxxx[y] = r8890.13
pxxxx[y] = r8890.14
pxxxx[y] = r8890.15
p0840[0] = r8890.0
p0844[0] = r8890.1
= ON (pulses can be enabled)
0 = OFF1 (braking with ramp-function generator, then pulse cancellation and ready for switching on)
1 = No coast-down activated (enable possible)
0 = Activate coast-down (immediate pulse cancellation and power-on inhibit)
1 = No quick stop activated (enable possible)
0 = Activate quick stop (braking along an OFF3 ramp p1135, then pulse cancellation and power- oninhibit)
1 = Enable operation (pulses can be enabled)
0 = Inhibit operation (cancel pulses)
= Acknowledge fault
Reserved
Reserved
Can be freely connected
Can be freely connected
Can be freely connected
Can be freely connected
Can be freely connected
[2501.3]
[2501.3]
[2546.1]
-
-
-
-
-
-
[2501.3]
[2501.3]
Signal targets for control word CANopen
[2610]
[2610]
[8060]
-
-
-
-
-
[2610]
[2610]
-
-
-
-
-
-
-
-
-
-
-
-
-
Signal
Interconnection
parameters
Meaning
[Function diagram]
internal control word
[Function diagram]
signal target
Inverted
<1>
CAN bus sampling time
<1> Depending on the position of the CANopen control word in p8750, the number of the binector to be connected changes.
<2> Ignored by automatic control word interconnection (p8790).
1 = Stop
STW1.4
STW1.5
STW1.6
p1140[0] = r8890.4
p1141[0] = r8890.5
p1142[0] = r8890.6
1 = Enable ramp-function generator
0 = Inhibit ramp-function generator
1 = Continue ramp-function generator
0 = Freeze ramp-function generator
1 = Enable speed setpoint ramp-function generator input
0 = Inhibit setpoint (the ramp-function generator input is set to zero)
[2501.3]
[2501.3]
[2501.1]
[3060]
[3060]
[3060]
-
-
-
<2>
<2>
<2>
<2>
<3>
[3060]
<3> Interconnection via p8791.

Table of Contents

Related product manuals