Siemens G130 - p1678[0...n] Speed actual value filter 5 denominator natural frequency; n_act_filt5 fn_den; p1679[0...n] Speed actual value filter 5 denominator damping; n_act_filt 5 D_den; p1680[0...n] Speed actual value filter 5 numerator natural frequency; n_act_filt5 fn_num; p1681[0...n] Speed actual value filter 5 numerator damping; n_act_filt 5 D_num

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
439
2 Parameters
2.2 List of parameters
Description: Sets the denominator natural frequency for speed actual value filter 5 (PT2, general filter).
Dependency: The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
Description: Sets the denominator damping for speed actual value filter 5.
Dependency: The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
Description: Sets the numerator natural frequency for speed actual value filter 5 (general filter).
Dependency: The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
Description: Sets the numerator damping for speed actual value filter 5.
Dependency: The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
Description: Activates data acceptance for parameter changes for the filter.
p1699 = 0:
The new filter data are immediately accepted.
p1678[0...n] Speed actual value filter 5 denominator natural frequency / n_act_filt5 fn_den
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 4715
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]
p1679[0...n] Speed actual value filter 5 denominator damping / n_act_filt 5 D_den
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 4715
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.001 10.000 0.700
p1680[0...n] Speed actual value filter 5 numerator natural frequency / n_act_filt5 fn_num
VECTOR_G (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 4715
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]
p1681[0...n] Speed actual value filter 5 numerator damping / n_act_filt 5 D_num
VECTOR_G (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 4715
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.000 10.000 0.700
p1699 Filter data acceptance / Filt data accept
VECTOR_G (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0 1 0