List Manual (LH2), 07/2016, A5E03263479A
439
2 Parameters
2.2 List of parameters
Description: Sets the denominator natural frequency for speed actual value filter 5 (PT2, general filter).
Dependency: The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
Description: Sets the denominator damping for speed actual value filter 5.
Dependency: The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
Description: Sets the numerator natural frequency for speed actual value filter 5 (general filter).
Dependency: The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
Description: Sets the numerator damping for speed actual value filter 5.
Dependency: The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
Description: Activates data acceptance for parameter changes for the filter.
p1699 = 0:
The new filter data are immediately accepted.
p1678[0...n] Speed actual value filter 5 denominator natural frequency / n_act_filt5 fn_den
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 4715
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]
p1679[0...n] Speed actual value filter 5 denominator damping / n_act_filt 5 D_den
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 4715
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.001 10.000 0.700
p1680[0...n] Speed actual value filter 5 numerator natural frequency / n_act_filt5 fn_num
VECTOR_G (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 4715
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]
p1681[0...n] Speed actual value filter 5 numerator damping / n_act_filt 5 D_num
VECTOR_G (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 4715
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.000 10.000 0.700
p1699 Filter data acceptance / Filt data accept
VECTOR_G (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0 1 0