EasyManua.ls Logo

Siemens G130 - F03505 (N, A) Analog input wire breakage; F03505 (N, A) TB: Analog input wire breakage; F03505 (N, A) TM: Analog input wire breakage

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1513
4 Faults and alarms
4.2 List of faults and alarms
Fault value (r0949, interpret decimal):
Note:
For the following analog input type, the wire breakage monitoring is active:
p0756[0] = 3 (4 ... 20 mA with monitoring)
Remedy: - check the wiring to the signal source for interruptions.
- check the magnitude of the injected current - it is possible that the infed signal is too low.
- check the load resistor (250 Ohm).
Note:
The input current measured by the analog input can be read in r0752[0].
For p756[0] = 3 (unipolar current input monitored (+4 ... +20 mA)) the following applies:
A current less than 4 mA is not displayed in r752[0] - but instead r752[0] = 4 mA is output.
Reaction upon N: NONE
Acknowl. upon N: NONE
Reaction upon A: NONE
Acknowl. upon A: NONE
F03505 (N, A) Analog input wire breakage
Message value: %1
Message class: External measured value / signal state outside the permissible range (16)
Drive object: B_INF, ENC, HUB, VECTOR_G
Component: Terminal Module (TM) Propagation: BICO
Reaction: OFF1 (NONE, OFF2)
Acknowledge: IMMEDIATELY (POWER ON)
Cause: The wire-break monitoring for an analog input has responded.
Remedy: Check the wiring for interruptions.
Reaction upon N: NONE
Acknowl. upon N: NONE
Reaction upon A: NONE
Acknowl. upon A: NONE
F03505 (N, A) TB: Analog input wire breakage
Message value: %1
Message class: External measured value / signal state outside the permissible range (16)
Drive object: TB30
Component: Terminal Module (TM) Propagation: BICO
Reaction: NONE
Acknowledge: IMMEDIATELY (POWER ON)
Cause: The wire-break monitoring for an analog input has responded.
Remedy: Check the wiring for interruptions.
Reaction upon N: NONE
Acknowl. upon N: NONE
Reaction upon A: NONE
Acknowl. upon A: NONE
F03505 (N, A) TM: Analog input wire breakage
Message value: %1
Message class: External measured value / signal state outside the permissible range (16)
Drive object: TM31
Component: Terminal Module (TM) Propagation: BICO
Reaction: NONE
Acknowledge: IMMEDIATELY (POWER ON)
Cause: The wire-break monitoring for an analog input has responded.
The input value of the analog input has exceeded the threshold value parameterized in p4061[x].
Index x = 0: Analog input 0 (X521.1/X521.2)
Index x = 1: Analog input 1 (X521.3/X521.4)