EasyManua.ls Logo

Siemens G130 - Fig. 3-173 8019 - Motor temperature model 3

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1293
3 Function diagrams
3.19 Signals and monitoring functions
Fig. 3-173 8019 – Motor temperature model 3
- 8019 -
Function diagram
87654321
fp_8019_54_eng.vsd
DO: SERVO, VECTOR
S120/S150/G130/G150
23.12.15 V04.08.00
Signals and monitoring functions - Thermal motor model 3
192.00 ms
<1> Only for SERVO.
<2> Only for VECTOR.
<3> Only if p0610.12 = 1.
0
1
0
1
A07012
"1/3 Thermal motor
model overtemperature"
[8016.1]
r0034
Mot_utiliz therm
[8016.6]
T0
Mot T_copper
r0632[M]
1
r0632  r5397
r5398  r5397
· 100 [%]
F thresh fig p5391
r5399
A thresh fig p5390
r5398
Only for:
synchronous motors
r0068[0]
I_act abs val unsmoothed
Activate thermal motor model 3
p0612.2[M](0)
State of breaking
r0063[1]
n_act smoothed with p0045
Mot T_rotor
r0633[M]
Mot T_stator
r0631[M]
Mot temp resp
p0610[M] (12)
<3>
r0063
n_act smooth
<2>
<1>
Thermal motor model 3