3 Function diagrams
3.23 Terminal Board 30 (TB30)
SINAMICS G130/G150
1324 List Manual (LH2), 07/2016, A5E03263479A
Fig. 3-200 9106 – Analog outputs (AO 0 ... AO 1)
- 9106 -
Function diagram
87654321
fp_9106_51_eng.vsd
DO: TB30
SINAMICS
25.10.05 V04.08.00
Terminal Board 30 (TB30) - Analog outputs (AO 0 ... AO 1)
AO 0
Scaling
p4082 [0]
(0)
Smoothing
Offset
-10.000...10.000 V
p4083[0] (0.000)
-1000.00...1000.00 %
p4079[0] (100.00 %)
-1000.00...1000.00 %
p4077[0] (0.00 %)
p4075 [0] (0)
-11.000...11.000 V
p4080[0] (10.000 V)
-11.000...11.000 V
p4078[0] (0.000 V)
X482.5
X482.6
D
A
[V]
r4074 [0]
r4072 [0]
[%]
0.0...1000.0 ms
p4073[0] (0.0)
AO 1
Scaling
p4082 [1]
(0)
Smoothing
Offset
-10.000...10.000 V
p4083[1] (0.000)
-1000.00...1000.00 %
p4079[1] (100.00 %)
-1000.00...1000.00 %
p4077[1] (0.00 %)
p4075 [1] (0)
-11.000...11.000 V
p4080[1] (10.000 V)
-11.000...11.000 V
p4078[1] (0.000 V)
X482.7
X482.8
D
A
[V]
r4074 [1]
r4072 [1]
[%]
0.0...1000.0 ms
p4073[1] (0.0)
Reference quantities
p2000... r2004
y
x
2
x
1
[%]
<1>
<1> The input signals are referred to the reference quantities p2004 ... r2004 (100 % p200x).
yx
xy
+ +
+
+
-11...+11 V
-11...+11 V
p4071 [1] (0)
p4071 [0] (0)
y
y
<1>
<1>
x
1
y
2
x
2
y
1
y
x
[%]
[V]
x
1
y
2
x
2
y
1
y
x
[%]
[V]
p4099[2] (4000.00 μs)
-1
0
1
-1
0
1
0
1
0
1
2
1
x
% 100x