2 Parameters
2.2 List of parameters
SINAMICS G130/G150
1032 List Manual (LH2), 07/2016, A5E03263479A
Description: Displays the data memory utilization as a result of Technology Extensions.
Index: [0] = Fast Memory 1
[1] = Fast Memory 2
[2] = Fast Memory 3
[3] = Fast Memory 4
[4] = Reserved
Dependency: Refer to: F01068
Note: TEC: Technology Extension
Description: Displays the calculated DRIVE-CLiQ system utilization based on the existing target topology.
The values are only available in the "Initialization finished" state (r3988 = 800).
Index 0 ... 7 corresponds to DRIVE-CLiQ socket X100 ... X107.
Dependency: Refer to: F01340
Description: Displays the calculated DRIVE-CLiQ bandwidth utilization based on the existing target topology.
The values are only available in the "Initialization finished" state (r3988 = 800).
Index 0 ... 7 corresponds to DRIVE-CLiQ socket X100 ... X107.
Dependency: Refer to: F01340
Description: Displays the calculated DRIVE-CLiQ DPRAM load based on the existing target topology.
The values are not made available until the RUNUP READY (800) state is adopted (see p3988).
Index 0 ... 7 corresponds to DRIVE-CLiQ socket X100 ... X107.
Dependency: Refer to: F01340
r9984[0...4] Data memory utilization TEC / Data mem util TEC
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r9986[0...7] DRIVE-CLiQ system load / DQ system load
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r9987[0...7] DRIVE-CLiQ bandwidth load / DQ bandw load
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r9988[0...7] DRIVE-CLiQ DPRAM load / DQ DPRAM load
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]