SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1273
3 Function diagrams
3.17 Technology functions
Fig. 3-155 7014 – External Armature Short-Circuit (EASC, p0300 = 2xx or 4xx)
- 7014 -
Function diagram
87654321
fp_7014_54_eng.vsd
DO: SERVO, VECTOR
S120/S150/G130/G150
04.05.16 V04.08.00
Technology functions - External Armature Short-Circuit (EASC, p0300 = 2xx or 4xx)
Drive converter
~
M
3
p1236 = 200 ms
=1
T
0
0T
p1237 = 200 ms
&
&
Pulse enable via hardware
1
Pulse inhibit (r0046.19 = 1)
r0046.4
r0046.20
1
Drive status S1, S2, S3, S4 not [2610]
p1231 = 1
r0002 = 19
2000 μs
Control Unit
DO
Contactor closed
r1239.0
p1231 = 2
(0)
ASC/DCBRK act
p1230
A07904
"Contactor feedback signal "Closed" missing"
F07905
"Contactor feedback signal "Open" missing"
+24 V
Contactor feedback signal
Pulse enable via hardware
1
DI
p1235
p1231 = 1
EASC: External Armature Short-Circuit
24 V
5 V