SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
621
2 Parameters
2.2 List of parameters
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 3rd value pair of the friction characteristic.
Dependency: Refer to: p3832, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 4th value pair of the friction characteristic.
Dependency: Refer to: p3833, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 5th value pair of the friction characteristic.
Dependency: Refer to: p3834, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 6th value pair of the friction characteristic.
Dependency: Refer to: p3835, p3845
p3822[0...n] Friction characteristic value n2 / Friction n2
VECTOR_G (n/M) Can be changed: T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Unit group: 3_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [rpm] 210000.00 [rpm] 60.00 [rpm]
p3823[0...n] Friction characteristic value n3 / Friction n3
VECTOR_G (n/M) Can be changed: T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Unit group: 3_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [rpm] 210000.00 [rpm] 120.00 [rpm]
p3824[0...n] Friction characteristic value n4 / Friction n4
VECTOR_G (n/M) Can be changed: T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Unit group: 3_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [rpm] 210000.00 [rpm] 150.00 [rpm]
p3825[0...n] Friction characteristic value n5 / Friction n5
VECTOR_G (n/M) Can be changed: T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Unit group: 3_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [rpm] 210000.00 [rpm] 300.00 [rpm]