2 Parameters
2.2 List of parameters
SINAMICS G130/G150
688 List Manual (LH2), 07/2016, A5E03263479A
Description: Display and connector output for the actual value XIST1_ERW.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: p4652, r4654, p4655
Description: Display and connector output for the actual value XIST1_ERW.
Dependency: Refer to: p4652, r4654, p4655
Description: Display and binector output to reset XIST1_ERW.
Dependency: Refer to: p4652, r4653, p4655
Note: The reset of XIST1_ERW is initiated via binector input p4655.
Binector output r4654 is reset with a 0 signal from binector input p4655.
Description: Display and binector output to reset XIST1_ERW.
Dependency: Refer to: p4652, r4653, p4655
Note: The reset of XIST1_ERW is initiated via binector input p4655.
Binector output r4654 is reset with a 0 signal from binector input p4655.
r4653[0...2] CO: XIST1_ERW actual value / XIST1_ERW actval
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: 4750
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r4653 CO: XIST1_ERW actual value / XIST1_ERW actval
ENC Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: 4750
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r4654.0...16 CO/BO: XIST1_ERW status / XIST1_ERW stat
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: 4750
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Encoder 1 XIST1_ERW reset High Low -
08 Geber 2 XIST1_ERW reset High Low -
16 Geber 3 XIST1_ERW reset High Low -
r4654.0 CO/BO: XIST1_ERW status / XIST1_ERW stat
ENC Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: 4750
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 XIST1_ERW reset High Low -