Siemens G130 - p4028 TM31 set input or output; TM31 DI or DO; p4030 BI: TM31 signal source for terminal DO 0; TM31 s_src DO 0; p4030 BI: TB30 signal source for terminal DO 0; TB30 s_src DO 0

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
643
2 Parameters
2.2 List of parameters
Dependency: Refer to: r4022
Note: DI: Digital Input
Description: Sets the bidirectional digital inputs/outputs as input or output on the Terminal Module 31 (TM31).
Note: DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for the digital output DO 0 (X542.1, X542.2, X542.3) of Terminal Module 31 (TM31).
Digital output 0 of TM31 is a relay output.
If the signal at the binector input p4030 is low, then terminal COM 0 (X542.2) is connected to NC 0 (X542.1). This
connection also matches the mechanical quiescent setting of the relay.
If the signal at the binector input p4030 is high, then terminal COM 0 (X542.2) is connected to NO 0 (X542.3).
Note: DO: Digital Output
NC: Normally Closed contact
NO: Normally Open contact
Description: Sets the signal source for digital output DO 0 (X481.5) of the Terminal Board 30 (TB30).
Note: DO: Digital Output
p4028 TM31 set input or output / TM31 DI or DO
TM31 Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: 9549, 9560,
9562
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
08 DI/DO 8 (X541.2) Output Input -
09 DI/DO 9 (X541.3) Output Input -
10 DI/DO 10 (X541.4) Output Input -
11 DI/DO 11 (X541.5) Output Input -
p4030 BI: TM31 signal source for terminal DO 0 / TM31 s_src DO 0
TM31 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 9549, 9556
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p4030 BI: TB30 signal source for terminal DO 0 / TB30 s_src DO 0
TB30 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 9099, 9102
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0