2 Parameters
2.2 List of parameters
SINAMICS G130/G150
624 List Manual (LH2), 07/2016, A5E03263479A
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 5th value pair of the friction characteristic.
Dependency: Refer to: p3824, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 6th value pair of the friction characteristic.
Dependency: Refer to: p3825, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 7th value pair of the friction characteristic.
Dependency: Refer to: p3826, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 8th value pair of the friction characteristic.
Dependency: Refer to: p3827, p3845
p3834[0...n] Friction characteristic value M4 / Friction M4
VECTOR_G (n/M) Can be changed: T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Unit group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
-1000000.0000 [Nm] 1000000.0000 [Nm] 0.0000 [Nm]
p3835[0...n] Friction characteristic value M5 / Friction M5
VECTOR_G (n/M) Can be changed: T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Unit group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
-1000000.0000 [Nm] 1000000.0000 [Nm] 0.0000 [Nm]
p3836[0...n] Friction characteristic value M6 / Friction M6
VECTOR_G (n/M) Can be changed: T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Unit group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
-1000000.0000 [Nm] 1000000.0000 [Nm] 0.0000 [Nm]
p3837[0...n] Friction characteristic value M7 / Friction M7
VECTOR_G (n/M) Can be changed: T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Unit group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
-1000000.0000 [Nm] 1000000.0000 [Nm] 0.0000 [Nm]