Fig. 3-138 6491 – Flux control configuration
- 6491 -
Function diagram
87654321
DO: VECTOR
S120/S150/G130/G150
14.04.14 V04.08.00
Vector control - Flux control configuration
1
2
1 = Flux setpoint soft starting active
Meaning
1 = Flux setpoint differentiation active
1 = Flux build-up control active
0
Bit No.
Flux control configuration
[6723.6]
[6722.3]
Flux ctrl config
p1401[D]
p1401[D]
Flux ctrl config
[6723.7]1
1
0
Factory setting
3 1 = Flux characteristic load-dependent 1
4 1 = Flux controller (ASM with encoder) 1
1 = Flux impression (ASM with encoder) with model chngov
0 = Flux impression (ASM with encoder) from 30 % n_rated
15
6 1
7 1 = Pre-control speed limitation 1
3
1 = Speed limiting controller with M_limits
0 = Speed limiting controller with I_limits
8
1 = Flux boost when establishing torque9
10 1 = Flux boost at low speed
11 Reserved
12 Reserved
1 = Quick magnetizing
13 Reserved
14 Reserved
15 Reserved
p0115[2] (Motor Modules)
fp_6491_54_eng.vsd
[6725.2]
[6722.5]
1
1
1