SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
227
2 Parameters
2.2 List of parameters
Description: Display and connector output for the time stamp MT_ZS_1 up to MT_ZS_16.
Displays the measuring time for an edge at the digital input for the "central measuring probe evaluation stage 3"
function.
The measuring time is specified as 16-bit value with a resolution of 0.25 µs.
Priority:
MT1 ... MT8, oldest ... newest time stamp
Description: Display and connector output for the time stamp reference MT_ZSB1 up to MT_ZSB4.
Description: Display and connector output for diagnostics word MT_DIAG.
Description: Sets the number of parameters in the inhibit list p0571.
This number of parameters can be automatically excluded from the calculation of the motor and control parameters
(see p0340, p0578), starting from index 0.
Note: Defines the number of entries in p0571 that should be taken into account.
The inhibit list is deactivated for a value of 0.
r0565[0...15] CO: Probe time stamp / Probe t_stamp
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0566[0...3] CO: Probe time stamp reference / Probe t_stamp name
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0567 CO: Probe diagnostics word / Probe diag_word
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p0570 Inhibit list values effective number / Inhib list no
VECTOR_G Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: Applications Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 50 0