Siemens G130 - r7208[0...n] Par_circuit power unit temperatures inverter 3; PU temp inv 3; r7209[0...n] Par_circuit power unit temperatures inverter 4; PU temp inv 4; r7210[0...n] Par_circuit power unit temperatures inverter 5; PU temp inv 5; r7211[0...n] Par_circuit power unit temperatures inverter 6; PU temp inv 6

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
761
2 Parameters
2.2 List of parameters
Description: Displays the inverter temperature 3 in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[7].
Description: Displays the inverter temperature 4 in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[8].
Description: Displays the inverter temperature 5 in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[9].
Description: Displays the inverter temperature 6 in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[10].
Description: Displays rectifier temperature 1 in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[11].
r7208[0...n] Par_circuit power unit temperatures inverter 3 / PU temp inv 3
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 21_1 Unit selection: p0505
Not for motor type: - Scaling: p2006 Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r7209[0...n] Par_circuit power unit temperatures inverter 4 / PU temp inv 4
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 21_1 Unit selection: p0505
Not for motor type: - Scaling: p2006 Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r7210[0...n] Par_circuit power unit temperatures inverter 5 / PU temp inv 5
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 21_1 Unit selection: p0505
Not for motor type: - Scaling: p2006 Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r7211[0...n] Par_circuit power unit temperatures inverter 6 / PU temp inv 6
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 21_1 Unit selection: p0505
Not for motor type: - Scaling: p2006 Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r7212[0...n] Par_circuit power unit temperatures inverter 1 / PU temp rect 1
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 21_1 Unit selection: p0505
Not for motor type: - Scaling: p2006 Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]

Table of Contents

Related product manuals