Description: Displays result list 2 that, for the crosswise data comparison between the monitoring channels, led to the fault.
Index: [0] = Result list second channel
[1] = Result list drive
Dependency: Refer to: C01711
Note: SCA: Safe Cam
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
Description: Displays the actual motor-side position actual value for the motion monitoring functions on the Control Unit.
Note: The display is updated in the safety monitoring clock cycle.
r9711[0...1] SI Motion diagnostics result list 2 / SI Mtn res_list 2
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Actual value > upper limit SCA1+ Yes No -
01 Actual value > lower limit SCA1+ Yes No -
02 Actual value > upper limit SCA1- Yes No -
03 Actual value > lower limit SCA1- Yes No -
04 Actual value > upper limit SCA2+ Yes No -
05 Actual value > lower limit SCA2+ Yes No -
06 Actual value > upper limit SCA2- Yes No -
07 Actual value > lower limit SCA2- Yes No -
08 Actual value > upper limit SCA3+ Yes No -
09 Actual value > lower limit SCA3+ Yes No -
10 Actual value > upper limit SCA3- Yes No -
11 Actual value > lower limit SCA3- Yes No -
12 Actual value > upper limit SCA4+ Yes No -
13 Actual value > lower limit SCA4+ Yes No -
14 Actual value > upper limit SCA4- Yes No -
15 Actual value > lower limit SCA4- Yes No -
16 Actual value > upper limit SSM+ Yes No -
17 Actual value > lower limit SSM+ Yes No -
18 Actual value > upper limit SSM- Yes No -
19 Actual value > lower limit SSM- Yes No -
20 Actual value > upper limit modulo Yes No -
21 Actual value > lower limit modulo Yes No -
r9712 CO: SI Motion diagnostics position actual value motor side / SI Mtn s_act mot
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -