2 Parameters
2.2 List of parameters
SINAMICS G130/G150
892 List Manual (LH2), 07/2016, A5E03263479A
Description: Sets the function for the component selected in p9210.
After initiating a function, the parameter is automatically reset again.
Example:
- set the component number (p9210).
- select the "flashing on" function (set p9211 = 1).
Value: -1: Select function
0: Flashing off
1: Flashing on
Dependency: Refer to: p9210
Notice: If a task cannot be executed (e.g. the component number in p9210 does not exist), the following applies:
- there is no negative feedback signal.
- the value is reset anyway.
Description: Displays the number of statistic entries in r9222.
Dependency: In p9221, the component Id is set whose statistical entries are to be displayed.
Refer to: p9221
Description: Selects the component Id whose statistics are to be displayed in r9222.
Description: Displays the statistics for the acyclic DRIVE-CLiQ communication of a component.
The component is preset in p9221.
The entry comprises the following elements:
Index 0: Parameter Id.
Index 1: Number of messages sent.
p9211 Flash function / Flash fct.
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Topology Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-1 1 -1
r9220 Statistics number of entries / Stat entries qty
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p9221 Statistic components Id / Statistic comp Id
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: T Calculated: - Access level: 4
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 00FF hex 0002 hex
r9222[0...n] Statistic DRIVE-CLiQ acyclic communication / Statistic
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: r9220 Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -