Command Manual – Multicast
H3C S7500E Series Ethernet Switches Chapter 1 IGMP Snooping Configuration Commands
1-25
This command works only on IGMP Snooping–enabled VLANs, but not on VLANs with
IGMP enabled on the corresponding VLAN interfaces.
Related commands: igmp-snooping last-member-query-interval.
Examples
# Set the interval between IGMP last-member queries globally to 3 seconds.
<Sysname> system-view
[Sysname] igmp-snooping
[Sysname-igmp-snooping] last-member-query-interval 3
1.1.28 max-response-time
Syntax
max-response-time interval
undo max-response-time
View
IGMP-Snooping view
Parameters
interval: Maximum response time to IGMP general queries, in units of seconds. The
effective range is 1 to 25.
Description
Use the max-response-time command to configure the maximum response time to
IGMP general queries globally.
Use the undo max-response-time command to restore the default value.
This command works only on IGMP Snooping–enabled VLANs, but not on VLANs with
IGMP enabled on the corresponding VLAN interfaces.
Related commands: igmp-snooping max-response-time, igmp-snooping
query-interval.
Examples
# Set the maximum response time to IGMP general queries globally to 5 seconds.
<Sysname> system-view
[Sysname] igmp-snooping
[Sysname-igmp-snooping] max-response-time 5