Command Manual – Information Center
H3C S7500E Series Ethernet Switches
Chapter 1 Information Center Configuration
Commands
1-25
undo info-center timestamp loghost
View
System view
Parameters
date: Indicates the current system date and time, the format of which depends on the
log host.
no-year-date: Indicates the current system date and time (year exclusive).
none: Indicates that no timestamp information is provided.
Description
Use the info-center timestamp loghost command to configure the timestamp format
of the system information sent to the log host.
Use the undo info-center timestamp loghost command to restore the default.
By default, the timestamp format for system information sent to the log host is date.
Examples
# Configure to exclude the year information in the time stamp of the system information
output to the log host.
<Sysname> system-view
[Sysname] info-center timestamp loghost no-year-date
1.1.24 info-center trapbuffer
Syntax
info-center trapbuffer [channel { channel-number | channel-name } | size buffersize ]
*
undo info-center trapbuffer [ channel | size ]
View
System view
Parameters
size buffersize: Specifies the maximum number of trap messages in a trap buffer, in the
range 0 to 1,024 with 256 as the default value.
channel-number: Specifies a channel number, in the range 0 to 9.
channel-name: Specifies a channel name, which could be a default name or a
self-defined name. The user needs to specify a channel name first before using it as a