EasyManua.ls Logo

H3C S7500E Series

H3C S7500E Series
1565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Manual – QinQ-BPDU Tunneling
H3C S7500E Series Ethernet Switches Chapter 1 QinQ Configuration Commands
1-4
[Sysname-Ethernet2/0/2] interface ethernet 2/0/3
[Sysname-Ethernet2/0/3] port link-aggregation group 1
[Sysname-Ethernet2/0/3] quit
[Sysname] port-group aggregation 1
[Sysname-port-group-aggregation-1] qinq enable
1.1.5 qinq ethernet-type customer-tag
Syntax
qinq ethernet-type customer-tag hex-value
undo qinq ethernet-type customer-tag
View
System view
Parameters
hex-value: Hexadecimal protocol type ID, in the range of 0x0001 to 0xFFFF, but you
cannot set it to any of the protocol type values listed in
Table 1-1.
Table 1-1 Common protocol type values
Protocol type Value
ARP 0x0806
PUP 0x0200
RARP 0x8035
IP 0x0800
IPv6 0x86DD
PPPoE 0x8863/0x8864
MPLS 0x8847/0x8848
IPX/SPX 0x8137
IS-IS 0x8000
LACP 0x8809
802.1x 0x888E
Cluster 0x88A7
Reserved 0xFFFD/0xFFFE/0xFFFF