EasyManua.ls Logo

H3C S7500E Series

H3C S7500E Series
1565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Manual – PoE
H3C S7500E Series Ethernet Switches Chapter 1 PoE Configuration Commands
1-37
Examples
# Set the AC input under-voltage threshold to 181 V.
<Sysname> system-view
[Sysname] poe-power input-threshold lower 181
# Set the AC input over-voltage threshold to 264 V.
<Sysname> system-view
[Sysname] poe-power input-threshold upper 264
1.1.33 poe-power output-threshold
Syntax
poe-power output-threshold { lower | upper } value
undo poe-power output-threshold { lower | upper }
View
System view
Parameters
lower value: Specifies an under-voltage threshold in volts, in the range 45 to 47, with
the default value being 45.
upper value: Specifies an over-voltage threshold in volts, in the range 55 to 57, with the
default value being 57.
Description
Use the poe-power output-threshold command to configure a DC output
under-voltage/over-voltage threshold.
Use the undo poe-power output-threshold command to restore the default.
Examples
# Set a DC output under-voltage threshold to 45 V.
<Sysname> system-view
[Sysname] poe-power output-threshold lower 45
# Set a DC output over-voltage threshold to 57 V.
<Sysname> system-view
[Sysname] poe-power output-threshold upper 57

Table of Contents

Other manuals for H3C S7500E Series

Related product manuals