Command Manual – Multicast
H3C S7500E Series Ethernet Switches Chapter 3 IGMP Configuration Commands
3-12
undo igmp last-member-query-interval
View
Interface view
Parameters
interval: IGMP last member query interval in seconds, with an effective range of 1 to 5.
Description
Use the igmp last-member-query-interval command to configure the last member
query interval, namely the length of time the device waits between sending IGMP
group-specific queries, on the current interface.
Use the undo igmp last-member-query-interval command to restore the system
default.
By default, the IGMP last member query interval is 1 second.
Related commands: last-member-query-interval, igmp robust-count, display igmp
interface.
Examples
# Set the IGMP last member query interval to 3 seconds on VLAN-interface 100.
<Sysname> system-view
[Sysname] interface vlan-interface 100
[Sysname-Vlan-interface100] igmp last-member-query-interval 3
3.1.11 igmp max-response-time
Syntax
igmp max-response-time interval
undo igmp max-response-time
View
Interface view
Parameters
interval: Maximum response time in seconds for IGMP general queries, with an
effective range of 1 to 25.
Description
Use the igmp max-response-time command to configure the maximum response
time for IGMP general queries on the current interface.
Use the undo igmp max-response-time command to restore the system default.