Command Manual – IPv6 Configuration
H3C S7500E Series Ethernet Switches Chapter 3 Tunneling Configuration Commands
3-3
<Sysname2> system-view
[Sysname2] interface Tunnel 1/0/3
[Sysname2-Tunnel1/0/3] source 192.100.1.1
[Sysname2-Tunnel1/0/3] destination 193.101.1.1
3.1.3 display interface tunnel
Syntax
display interface tunnel [ number ]
View
Any view
Parameters
number: Tunnel interface number. If the number argument is not specified, the
information of all tunnel interfaces will be displayed.
Description
Use the display interface tunnel command to display related information of a
specified tunnel interface, such as source address, destination address, and
encapsulation mode.
Related commands: interface tunnel, source, destination, tunnel-protocol.
Examples
# Display the information of the interface Tunnel 1/0/3.
<Sysname> display interface Tunnel1/0/3
Tunnel1/0/3 current state: UP
Line protocol current state: UP
Description: Tunnel1/0/3 Interface
The Maximum Transmit Unit is 64000
Internet Address is 10.1.2.1/24 Primary
Encapsulation is TUNNEL, aggregation ID not set
Tunnel source 192.13.2.1, destination 192.13.2.2
Tunnel protocol/transport IPv6/IP
Last 300 seconds input: 0 bytes/sec, 0 packets/sec
Last 300 seconds output: 0 bytes/sec, 0 packets/sec
361 packets input, 9953388 bytes
0 input error
361 packets output, 30324 bytes
0 output error