Command Manual – PoE
H3C S7500E Series Ethernet Switches Chapter 1 PoE Configuration Commands
1-13
Field Description
PSE Power Enabled PoE is enabled for the PSE
PSE Power Preempted
PSE power preempted state
z no: The power of the PSE is not preempted.
z yes: The power of the PSE is preempted so that
it cannot supply power, although PoE is
enabled for the PSE
PSE Power Priority Power priority of the PSE
PSE Current Power Current power of the PSE
PSE Average Power Average power of the PSE
PSE Peak Power Peak power of the PSE
PSE Max Power Maximum power of the PSE
PSE Remaining Guaranteed
Guaranteed remaining power of the PSE =
Maximum power of the PSE– the sum of the
maximum power of the critical PoE interfaces of
the PSE
PSE CPLD Version PSE CPLD version
PSE Software Version PSE software version number
PSE Hardware Version PSE hardware version number
PSE Legacy Detection
Nonstandard PD detection by the PSE:
z enable: Enabled
z disable: Disabled
PSE Utilization-threshold PSE power alarm threshold
PSE Pse-policy Mode PSE power management policy mode
PSE Pd-policy Mode PD power management policy mode
PSE PD Disconnect Detect
Mode
PD disconnection detection mode
1.1.8 display poe-power
Syntax
display poe-power
View
Any view
Parameters
None