EasyManuals Logo

H3C S7500E Series Command Manual

H3C S7500E Series
1565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #153 background imageLoading...
Page #153 background image
Command Manual – Port Correlation Configuration
H3C S7500E Series Ethernet Switches
Chapter 1 Ethernet Port Configuration
Commands
1-20
1.1.18 loopback-detection interval-time
Syntax
loopback-detection interval-time time
undo loopback-detection interval-time
View
System view
Parameters
time: Time interval for performing port loopback detection, in the range 5 to 300 (in
seconds).
Description
Use the loopback-detection interval-time command to configure time interval for
performing port loopback detection.
Use the undo loopback-detection interval-time command to restore the default time
interval for port loopback detection, which is 30 seconds.
Related commands: display loopback-detection.
Examples
# Set the time interval for performing port loopback detection to 10 seconds.
<Sysname> system-view
[Sysname] loopback-detection interval-time 10
1.1.19 loopback-detection per-vlan enable
Syntax
loopback-detection per-vlan enable
undo loopback-detection per-vlan enable
View
Ethernet port view
Parameters
None
Description
Use the loopback-detection per-vlan enable command to enable loopback detection
in all VLANs with Trunk ports or Hybrid ports.

Table of Contents

Other manuals for H3C S7500E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S7500E Series and is the answer not in the manual?

H3C S7500E Series Specifications

General IconGeneral
BrandH3C
ModelS7500E Series
CategorySwitch
LanguageEnglish

Related product manuals