EasyManuals Logo

H3C S7500E Series Command Manual

H3C S7500E Series
1565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1479 background imageLoading...
Page #1479 background image
Command Manual – PoE
H3C S7500E Series Ethernet Switches Chapter 1 PoE Configuration Commands
1-16
Output AC Current A Alarm : Normal
Output AC Current B Alarm : Under Limit
Output AC Current C Alarm : Lack Phase
Module 1:
Volt Phase AB Alarm : Above Limit
Volt Phase BC Alarm : Fuse Broken
Volt Phase CA Alarm : Switch Off
Module 2:
Volt Phase AB Alarm : Above Limit
Volt Phase BC Alarm : Fuse Broken
Volt Phase CA Alarm : Switch Off
Table 1-8 Description on the fields of display poe-power ac-input state
Field Description
Module Number
Number of modules that a power supply unit (PSU)
contains
Output AC Current
A/B/C Alarm
Output three-phase AC voltage state:
z Normal: The voltage is normal.
z Under Limit: The voltage is below the lower limit.
z Above Limit: The voltage is above the upper limit.
z Lack Phase: A phase is lost.
z Fuse Broken: The fuse is broken.
z Switch Off: The switch is turned off.
z Other Error: Other faults
Volt Phase AB/BC/CA
Alarm
AC voltage input state: Same as those of the output
three-phase AC current
1.1.10 display poe-power alarm
Syntax
display poe-power alarm
View
Any view
Parameters
None
Description
Use the display poe-power alarm command to display the alarm information of the
PoE power.

Table of Contents

Other manuals for H3C S7500E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S7500E Series and is the answer not in the manual?

H3C S7500E Series Specifications

General IconGeneral
BrandH3C
ModelS7500E Series
CategorySwitch
LanguageEnglish

Related product manuals