EasyManua.ls Logo

H3C S7500E Series

H3C S7500E Series
1565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Manual – 802.1x - MAC Authentication
H3C S7500E Series Ethernet Switches
Chapter 2 EAD Fast Deployment
Configuration Commands
2-2
2.1.2 dot1x timer ead-timeout
Syntax
dot1x timer ead-timeout ead-timeout-value
undo dot1x timer ead-timeout
View
System view
Parameters
ead-timeout-value: EAD rule timeout time, in the range 1 minute to 1440 minutes.
Description
Use the dot1x timer ead-timeout command to set the EAD rule timeout time.
Use the undo dot1x timer ead-timeout command to restore the default.
By default, the timeout time is 30 minutes.
Related commands: display dot1x.
Examples
# Set the EAD rule timeout time to 5 minutes.
<Sysname> system-view
[Sysname] dot1x timer ead-timeout 5
2.1.3 dot1x url
Syntax
dot1x url url-string
undo dot1x [ url-string ]
View
System view
Parameters
url-string: Redirect URL, a case-sensitive string of 1 to 64 characters in the format
http://string.
Description
Use the dot1x url command to configure a URL to which the system redirects users’
HTTP access before they pass 802.1x authentication.
Use the undo dot1x url command to remove the redirect URL.

Table of Contents

Other manuals for H3C S7500E Series

Related product manuals