Command Manual – Information Center
H3C S7500E Series Ethernet Switches
Chapter 1 Information Center Configuration
Commands
1-14
Description
Use the info-center logbuffer command to enable information output to a log buffer
and set the corresponding parameters.
Use the undo info-center logbuffer command to disable information output to a log
buffer.
By default, information output to the log buffer is enabled with channel 4 (logbuffer) as
the default channel and a maximum buffer size of 512.
Note that the info-center logbuffer command takes effect only after the information
center is enabled with the info-center enable command.
Examples
# Enable the system to output information to the log buffer using channel 4, with a
default buffer size of 50.
<Sysname> system-view
[Sysname] info-center logbuffer size 50
1.1.12 info-center logfile enable
Syntax
info-center logfile enable
undo info-center logfile enable
View
System view
Parameters
None
Description
Use the info-center logfile enable command to enable the output of system
information to the log file.
Use the undo info-center logfile enable command to disable the output of system
information to the log file.
By default, the output of system information to the log file is enabled.
Examples
# Enable the log file feature.
<Sysname> system-view
[Sysname] info-center logfile enable