Command Manual – System Maintaining and Debugging
H3C S7500E Series Ethernet Switches
Chapter 2 System Maintaining and
Debugging Commands
2-4
<Sysname> ping ipv6 2001::1
PING 2001::1 : 56 data bytes, press CTRL_C to break
Reply from 2001::1 bytes=56 Sequence=1 hop limit=64 time = 20 ms
Reply from 2001::1 bytes=56 Sequence=2 hop limit=64 time = 0 ms
Reply from 2001::1 bytes=56 Sequence=3 hop limit=64 time = 0 ms
Reply from 2001::1 bytes=56 Sequence=4 hop limit=64 time = 0 ms
Reply from 2001::1 bytes=56 Sequence=5 hop limit=64 time = 0 ms
--- 2001::1 ping statistics ---
5 packet(s) transmitted
5 packet(s) received
0.00% packet loss
round-trip min/avg/max = 0/4/20 ms
The “hop limit” field in this prompt information has the same meaning as the “ttl” field in
the prompt information displayed by the IPv4 ping command, indicating the TTL value
in the ICMPv6 echo request.
2.1.3 tracert
Syntax
tracert [ -a source-ip | -f first-ttl | -m max-ttl | -p port | -q packet-number | -w timeout ] *
remote-system
View
Any view
Parameters
-a source-ip: Specifies the source IP address of a tracert packet. It must be a legal IP
address configured on the device.
-f first-ttl: Specifies the first TTL, that is, the allowed number of hops for the first packet,
in the range 1 to 255. It defaults to 1 and must be less than the maximum TTL.
-m max-ttl: Specifies the maximum TTL, that is, the maximum allowed number of hops
for a packet, in the range 1 to 255. It defaults to 30, and must be greater than the first
TTL.
-p port: Specifies the UDP port number of the destination device, in the range 1 to
65535. The default value is 33434. You do not need to modify this parameter.
-q packet-number: Specifies the number of probe packets sent each time, in the range
1 to 65535. The default value is 3.
-w timeout: Specifies the packet timeout time, in the range 1 to 65535, in milliseconds.
The default value is 5000 ms.

Table of Contents

Other manuals for H3C S7500E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S7500E Series and is the answer not in the manual?

H3C S7500E Series Specifications

General IconGeneral
BrandH3C
ModelS7500E Series
CategorySwitch
LanguageEnglish

Related product manuals