Command Manual – System Maintaining and Debugging
H3C S7500E Series Ethernet Switches Chapter 3 Device Management Commands
3-6
View
Any view
Parameters
cf-card: Displays information of a compact Flash (CF).
shelf shelf-number: Displays detailed information of the specified shelf or unit. The
shelf-number argument represents a shelf number or unit number and the value range
varies with devices.
frame frame-number: Displays detailed information of the specified frame. The
frame-number argument represents a frame number and the value range varies with
devices.
slot slot-number: Displays detailed information of the specified card. The slot-number
argument represents the slot number of a card and the value range varies with devices.
verbose: Displays detailed information.
Description
Use the display device command to display information about storage media such as
card, subcard, and CF card.
Examples
# Display brief information of cards on the device.
<Sysname> display device
Slot No. Brd Type Brd Status Subslot Num Sft Ver
0 NONE Absent 0 NONE
1 LSQ1MPUA Master 0 V600R001B02D036
2 LSQ1FV48SA Normal 0 V600R001B02D036
3 NONE Absent 0 NONE
# Display detailed information of cards on the device.
<Sysname> display device verbose
Slot No. Brd Type Brd Status Subslot Num Sft Ver
0 NONE Absent 0 NONE
1 LSQ1MPUA Master 0 V600R001B02D036
2 LSQ1FV48SA Normal 0 V600R001B02D036
3 NONE Absent 0 NONE
Slot 1 info:
Status : Master
Type : LSQ1MPUA
PCB Ver : VER.A
FPGA Ver : 001
BootRom Ver : 108