Command Manual – Multicast
H3C S7500E Series Ethernet Switches Chapter 3 IGMP Configuration Commands
3-23
3.1.24 robust-count
Syntax
robust-count robust-value
undo robust-count
View
IGMP view
Parameters
robust-value: IGMP querier robustness variable, with an effective range of 2 to 5. The
IGMP robustness variable determines the number of general queries the IGMP querier
sends on startup and the number of IGMP group-specific queries the IGMP querier
sends upon receiving an IGMP leave message.
Description
Use the robust-count command to configure the IGMP querier robustness variable
globally.
Use the undo robust-count command to restore the system default.
By default, the IGMP querier robustness variable is 2.
Related commands: igmp robust-count, timer query, last-member-query-interval,
timer other-querier-present, display igmp interface.
Examples
# Set the IGMP querier robustness variable to 3 globally.
<Sysname> system-view
[Sysname] igmp
[Sysname-igmp] robust-count 3
3.1.25 send-router-alert
Syntax
send-router-alert
undo send-router-alert
View
IGMP view
Parameters
None

Table of Contents

Other manuals for H3C S7500E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S7500E Series and is the answer not in the manual?

H3C S7500E Series Specifications

General IconGeneral
BrandH3C
ModelS7500E Series
CategorySwitch
LanguageEnglish

Related product manuals