Command Manual – VLAN
H3C S7500E Series Ethernet Switches Chapter 4 GARP/GVRP Configuration Commands
4-3
Parameters
hold: Sets the hold timer.
join: Sets the join timer.
leave: Sets the leave timer.
timer-value: Timer setting (in centiseconds), which must be a multiple of 5
centiseconds.
Description
Use the garp timer command to set a GARP timer for an Ethernet port or all ports in a
port group in compliance with the timer setting dependencies shown in
Table 4-1.
Use the undo garp timer command to restore the default of a GARP timer. This may
fail if the default does not satisfy the dependencies shown in
Table 4-1.
By default, the hold timer, the join timer, and the leave timer are set to 10 centiseconds,
20 centiseconds, and 60 centiseconds.
Note that:
z In Ethernet port view, these two commands apply to the current port only; in port
group view, these two commands apply to all the ports in the port group.
z When restoring the default GARP timers, you are recommended to do that on the
timers in the order of hold, join, leave, and leaveall.
z When configuring GARP timers, note that their values are dependent on each
other and must be a multiplier of five centiseconds. If the value range for a timer is
not desired, you may change it by tuning the value of another timer as shown in
the following table:
Table 4-1 Dependencies of GARP timers
Timer Lower limit Upper limit
Hold
10 centiseconds
Not greater than half of
the join timer setting
Join
Not less than two times the hold timer
setting
Less than half of the
leave timer setting
Leave
Greater than two times the join timer
setting
Less than the leaveall
timer setting
Leaveall
Greater than the leave timer setting
32765 centiseconds
Related commands: display garp timer.
Examples
# Set the GARP join timer to 25 centiseconds, assuming that both the hold timer and
the leave timer are using the default.

Table of Contents

Other manuals for H3C S7500E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S7500E Series and is the answer not in the manual?

H3C S7500E Series Specifications

General IconGeneral
BrandH3C
ModelS7500E Series
CategorySwitch
LanguageEnglish

Related product manuals