LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1033 of 1904 2022-03-04
Not Subject to NDA
- On Active/MT/MO Voice Call return Error.
- Clock 4096KHz don't supported with Sample Rate 8KHz
- #DVICFG return Error, when <clock> enabled.
- On Clock value zero (0) the clock rate and sample rate taken from
#DVICFG <clock> value.
- This parameter is saved in NVM issuing AT&W command.
- The command works only for PCM mode (#DVIEXT=0)
- #DVICLK return Error, when I2S mode (#DVIEXT=1)
- #DVICLK return Error, when clock always on mode (#DVI=1,2,2)
For LE910Cx ThreadX product:
- Clock 2048KHz supports only Sample Rate 8KHz.
- Clock 4096KHz supports only Sample Rate 16KHz.
- Both <clock> and <samplerate> should be entered.
#DVICLK return Error, if only <clock> is enter.
- Factory default is <clock> 2048 and <samplerate> 0(8KHz).
- Not support #DVICFG.
- Not supports <clock> 0, <clock> 128, <clock> 256, <clock> 512,
<clock> 1024.
- This parameter is not save in NVM.
AT#DVICLK?
Read command reports last setting, in the format:
#DVICLK: <clock>,<samplerate>
AT#DVICLK=?
Test command reports the range of parameter <clk> and <samplerate>.