LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 783 of 1904 2022-03-04
Not Subject to NDA
3.9.7. AT+CGCONTRDP - PDP Context Read Dynamic Parameters
The execution command returns the relevant information for a PDP Context established
by the network.
3GPP TS 27.007
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Auto
No
-
2
AT+CGCONTRDP[=<cid>]
The execution command returns the relevant information on a PDP Context
established by the network with the context identifier <cid>. If the parameter
<cid> is omitted, the information for all established PDP contexts is returned. The
response message has the following format:
+CGCONTRDP:<cid>,<bearerId>,<apn>[,<ip&subnet>[,<gw_addr>[,<DNS_prim>
[,<DNS_sec>[,<P_CSCF_prim>[,<P_CSCF_sec>]]]]]][<CR><LF>
+CGCONTRDP:<cid>,<bearerId>,<apn>[,<ip&subnet_mask>[,<gw_addr>[,<DNS_pr
im>
[,<DNS_sec>[,<P_CSCF_prim>[,<P_CSCF_sec>]]]]]] [...]]
If the context cannot be found an ERROR response is returned.
The response message parameters are described in the Additional info section.
If the parameter <cid> is omitted, the relevant information for all active non
secondary PDP contexts is returned.
Parameter:
Name
Type
Default
Description
<cid>
integer
-
identifies a non secondary PDP context
definition. The parameter is local to the TE-
MT interface and is used in other PDP
context-related commands.