EasyManuals Logo

Telit Wireless Solutions LE910C series At Commands Reference Guide

Telit Wireless Solutions LE910C series
1904 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1840 background imageLoading...
Page #1840 background image
LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1840 of 1904 2022-03-04
Not Subject to NDA
3.35.6. AT#BREAD - BLE Read
This command is used to read the BLE characteristics value of a service.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
No
No
-
2
AT#BREAD=<Connection Handle>,<Characteristic Handle>
Set command is used to read the characteristics value of a service.
Parameters:
Name
Type
Default
Description
<Connection
Handle>
hex
N/A
It specifies the connection handle
returned during BLE connect
command.
Value:
0x1÷0xFFFF
:
The supported parameter value
range.
<Characteristic
Handle>
hex
N/A
It specifies the characteristic
handle returned during service
discovery.
Value:
0x1÷0xFFFF
:
The supported parameter value
range.
AT#BREAD=?
Test command reports supported range of values for all parameters.

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C series and is the answer not in the manual?

Telit Wireless Solutions LE910C series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C series
CategoryWireless modules
LanguageEnglish

Related product manuals