LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1870 of 1904 2022-03-04
Not Subject to NDA
3.35.19. AT#BCONINTMIN - BLE Minimum Connection Interval
This command is used to configure the BLE minimum connection interval.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
No
No
-
2
AT#BCONINTMIN=<Minimum Connection Interval>
Set command is used to configure the minimum connection interval for a
Bluetooth Low Energy connection.
Parameter:
Name
Type
Default
Description
<Minimum
Connection
Interval>
integer
N/A
It specifies the minimum
connection interval for a Bluetooth
Low Energy connection in
milliseconds.
Value:
8÷4000
:
The supported parameter value range.
This value can be saved into profile
through AT#W command.
AT#BCONINTMIN?
Read command is used to get the status of the minimum connection
interval:
#BCONINTMIN: <Minimum Connection Interval>
Where,
<Minimum Connection Interval> - Specifies the minimum connection
interval. For example:
AT#BCONINTMIN?
#BCONINTMIN: 400

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C series and is the answer not in the manual?

Telit Wireless Solutions LE910C series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C series
CategoryWireless modules
LanguageEnglish

Related product manuals