3.15.27. AT#VAUXSAV - Auxiliary Voltage Output Save
This command allows to save the current state of the Auxiliary Voltage output pin in
NVM.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
No
No
-
2
AT#VAUXSAV
Execution command saves the current state of VAUX pin in NVM. The
state will be reloaded at the next power on.
AT#VAUXSAV=?
Test command returns OK result code.