LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1166 of 1904 2022-03-04
3.15.30. AT#TESTMODE - Test Mode Configuration
Set module in test mode for configuring and testing the POWER level.
AT#TESTMODE=<cmd>
The command allows to execute some CT commands through AT
interface. The functionality has to be first activated by sending
AT#TESTMODE="TM", which sets the module in Test Mode. Only after this
set, AT#TESTMODE can be used with the other allowed CT commands. To
exit from Test Mode and go back to Operative Mode, the command
AT#TESTMODE ="OM" has to be sent.
AT#TESTMODE= "CT_command"
Parameter:
"CT_command": this string corresponds to a
CT command. To be accepted by
AT#TESTMODE, the CT command has to
belong to the following list of CT commands
enabled for this use:
forces the module in Test
Mode
forces the module in
Operative Mode
returns the list of
supported bands
sets the band of used
technology (tunes the RF