3.15.9. AT#TEMPCFG - Temperature Monitor Configuration
Set command sets the temperature zones shown in Note section. Use #TEMPMON
command to get the current internal temperature of the module.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT#TEMPCFG=<etlz_clr>,<etlz>,<etlz_act_in>,<otlz_clr>,<otlz>,<otlz_act_in>,<otnz
_clr>,<otnz>,<otnz_act_in>,<otuz_clr>,<otuz>,<otuz_act_in>,
<etuz_clr>,<etuz>,<etuz_act_in>
Set command sets the Temperature zones used in the #TEMPMON command.
Parameters:
Name
Type
Default
Description
<etlz_clr>
integer
-273
extreme low zone temperature
threshold clear.
Value:
-
273
:
degree C (See note.)
<etlz>
integer
-33
extreme low zone temperature
threshold.
Value:
-40÷105
:
degree C
<etlz_act_in>
integer
0
extreme low zone action info.
Value:
0÷5
:
action
<otlz_clr>
integer
-35
operate low zone temperature
threshold clear.