3.12.7.9. AT#ACDBEXT - Extended Control the ACDB(Audio Calibration Database) file
This command used to store ACDB(Audio Calibration Database) file on file system or to
read current size of specific ACDB file or select the ACDB file to be loaded into the
module.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT#ACDBEXT=<mode>,<slot>[,<category>[,<size>]]
Set command to store <category> acdb file on FS or to return the current
size in Bytes of specific <category> file or Select the acdb file to be loaded
into the module.
Parameters:
Name
Type
Default
Description
<mode>
integer
N/A
required action
Values:
0
:
Store file on FS
1
:
Returns the current <size> of the <category> file
2
:
Select the acdb files of <slot> to be loaded into the
module
<slot>
integer
0
Slot
Values:
0
:
Slot 0
1
:
Slot 1
2
:
Slot 2
3
:
Slot 3