3.7.9. AT#WAKE - Wake from Alarm Mode
Stop any alarm activity
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
No
No
-
2
AT#WAKE=<opmode>
Execution command stops any eventually present alarm activity and, if the
module is in alarm mode, it exits the alarm mode and enters the normal
operating mode.
Parameter:
Name
Type
Default
Description
<opmode>
integer
0
operating
mode
Value:
0
:
normal operating mode; the module exits the alarm
mode and enters the normal operating mode, any
alarm activity is stopped (e.g. alarm tone playing)
and an OK result code is returned.
If #WAKE=0 command is issued after an alarm has been set with
+CALA command, but before the alarm has expired, it will answer
OK but have no effect.
AT#WAKE?
Read command returns the operating status of the device in the format:
#WAKE: <status>
where:
<status>

Table of Contents

Other manuals for Telit Wireless Solutions LE910C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910C series and is the answer not in the manual?

Telit Wireless Solutions LE910C series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910C series
CategoryWireless modules
LanguageEnglish

Related product manuals