LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14 Page 1578 of 1904 2022-03-04
3.25.5. AT#DWLRCV - List Information on Messages Pending from IoT Portal
This command allows the users to get the list of the incoming messages from IoT
Portal.
AT#DWLRCV
Execution command reports the list of the pending messages from IoT
Portal in the following format:
#DWLRCV:<msg_number>[,<msgId_1>,<msg_1_len>[,
...<msgId_N>,<msg_N_len>]]
Additional info:
number of messages
pending from IoT Portal (at
least 0)
index of the i-th data
message to receive
length of the i-th data
message to receive
It is possible to use #DWLRCV only if the connection has been